Technical indicators | |||
NO. | Name | Indicator | Remarks |
1 | Product nitrogen output | ≥100m³/h | gas volume reading display |
2 | Product nitrogen purity | ≥99.99% | non-oxygen content,nitrogen purity online display |
3 | Nitrogen outlet pressure | ≤0.6Mpa | pressure reading display |
4 | Nitrogen oil content | ≤0.01ppm | |
5 | Operation mode Fully | automatic operation | |
6 | Nitrogen generator power supply | 220V/50HZ or 220V/60HZ | |
7 | Installed power of nitrogen generator | 0.3KW | |
Main supporting equipment technical parameters | |||
1.Technical parameters of screw air compressor | |||
No. | Performance Index | Technical Parameters | Unit |
1 | Model | G-75A | |
2 | Process air volume | 10 | Nm³/min |
3 | Exhaust pressure | 0.8 | Mpa |
4 | Cooling method | Air cooling | |
5 | Working voltage | 380/50 | V/Hz |
6 | Power | 55 | Kw |
7 | Device size | 1950×1060×1600 | mm |
8 | Equipment weight | 1220 | KG |
2.Technical parameters of high temperature refrigerated dryer | |||
No. | Performance Index | Technical Parameters | Unit |
1 | Model | HX-010GF | 汉粤 |
2 | Process air volume | 11.5 | Nm³/min |
3 | Exhaust pressure | 0.6Mpa——1.0Mpa | Mpa |
4 | Cooling method | Air cooling | |
5 | Working voltage | 380/50HZ | V/Hz |
6 | Device size | 1150×980×1305 | mm |
7 | Equipment weight | 148 | KG |
8 | Power | 2.22 | KW |
3.Four-stage precision filter (C-T-A-AA) | |||||
No. | Item | Detailed parameters | |||
1 | filter name | Class C centrifugal oil-water separator | Class T main line filter | Class A micro oil mist filter | AA grade super high efficiency filter |
2 | Filtration accuracy | 3um | 1um | 0.01u | 0.01u |
3 | water removal rate | 100% | 100% | Residual oil rate: 0.01ppm | Residual oil rate: 0.001ppm |
4 | Oil mist removal rate | 70% | 100.00% | ||
5 | Filter material | Micro glass fiber | Micro glass fiber | Microfiber glass with activated carbon powder | Microfiber glass with activated carbon powder |
6 | Filter life | 8000 hours | 8000 hours | 8000 hours | 8000 hours |
7 | work pressure | Standard 0.7Mpa, maximum 1.0Mpa | |||
8 | Intake air temperature | <66℃ | |||
9 | initial pressure drop | >0.015Mpa | |||
10 | select attachment | automatic drain |
4.Oil-free nitrogen booster | |||
No. | Performance Index | Technical Parameters | Unit |
1 | Model | WWZ-100/5-20 | |
2 | Handling gas volume | 100 | Nm³/h |
3 | Intake pressure | 0.5 | Mpa |
4 | Outlet pressure | 2 | Mpa |
5 | Operating Voltage | 380/50 | V/Hz |
6 | Power | 15 | KW |
7 | Equipment weight | 480 | KG |
8 | Equipment size | 1700*1100*1200 |